Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Timur

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Fluke 317 Clamp Meters

Fluke 317 Clamp Meters

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit
Dilihat Sebanyak
:
4 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 317 Clamp Meters

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A ( 319) in tight cable compartments. The Fluke 317and 319 also offer AC/ DC current measurements and have a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equips with In-rush current and Frequency functions for testing motors, lighting, etc. General Specifications Digital Display 6000 count resolution Low Battery Indication Displays a signal when the batteries are below their required voltage Power Source Three AAA IEC LR03 batteries Clamp Opening Size 1.45 in ( 37 mm) Jaw Diameter 1.45 in ( 37 mm) Dimensions ( L x W x H) 6.39 in x 2.29 in x 1.20 in ( 162.4 mm x 58.25 mm x 30.5 mm) Weight approximately 13.5 oz ( 384 g) ( batteries included) Auto Range Available in Ohms Safety CE EN/ IEC 61010-1 and IEC 61010-2-032 Measurement Category: 600V CAT III 317 Electrical Specifications Current AC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 50-60 Hz) { 40 A} 2.5% ± 8 digit ( 60-500 Hz) { 40 A} 1.5% ± 5 digit ( 50-60 Hz) { 600 A} 2.5% ± 5 digit ( 60-500 Hz) { 600 A} Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A AC response rms Current DC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 40 A) 1.5% ± 5 digit ( 600 A) Voltage AC Range 600.0 V Resolution 0.1 V Accuracy 1.5% ± 5 digit ( 20-500Hz) AC response rms Voltage DC Range 600.0 V Resolution 0.1 V Accuracy 1% ± 4 digit Resistance Range 400.0 © , 4000 © Resolution 0.1 © , 1 © Accuracy 1% ± 5 digit Continuity d 30 © Inrush Integration time N/ A Frequency Range N/ A Accuracy N/ A Trigger Level N/ A The accuracy specifications aply at 73 ° F ± 41 ° F ( 23 ° C ± 5 ° C) Below 64 ° F and above 82 ° F ( 18 ° C and above 28 ° C) accuracy degrades at ( 0.1) times specification per ° C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. Environmental Specifications Operating Temperature 14° F to 122° F ( -10 ° C to 50 ° C) Storage Temperature -40 ° F to 140 ° F ( -40 ° C to 60 ° C) Operating Humidity Non condensing ( < 50 ° F) ( < 10 ° C) 90 % RH ( 50 ° F to 86 ° F) ( 10 ° C to 30 ° C) 75 % RH ( 86 ° F to 104 ° F) ( 30 ° C to 40 ° C) 45 % RH ( 104 ° F to 122 ° F) ( 40 ° C to 50 ° C) ( Without Condensation) Operating Altitude 1 mile ( 2000 meters) above mean sea level Storage Altitude 7 miles ( 12, 000 meters) above mean sea level IP Rating IP40 Vibration Requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis Drop Test Requirements 3 ft ( 1 m) drop test, six sides, oak floor EMI, RFI, EMC Instrument unspecified for use in EMC field e 0.1 V/ m Temperature Coefficients 0.1x ( specified accuracy) / ° C ( 82° F) ( 28 ° C)

Tampilkan Lebih Banyak