Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Timur

Bergabung Selama :

BAGIKAN :   

Bagikan :

FLUKE 289 TRUE RMS MULTIMETER

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit
Dilihat Sebanyak
:
8 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail FLUKE 289 TRUE RMS MULTIMETER

Features & Applications: The Fluke 289 True-RMS Industrial Logging Multimeter enables you to empower yourself and solve complex problems in electronics, plant automation, power distribution and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and minimize costly downtime.. Features: Large 50, 000 count, ¼ VGA display with white backlight. TrendCapture Log multiple sessions or log data continuously for over 200 hours. This is useful for characterizing the performance of a design or for unattended monitoring i-info button on board help screens for measurement functions. Unsure about a function? Go to that function and Press the “ i” button LoZ Volts. Low impedance voltage function prevents false readings due to “ ghost voltage.” It is also the recommended mode when testing for absence or presence of live power Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current Saved measurements allow you to name and recall measurements made in the field Real Time Clock – for automatic time stamping of saved readings Field upgradeable and expandable meter lets you stay current as new capabilities are added Multi-lingual interface Min/ Max/ Average with Time Stamp to record signal fluctuations Soft keys, scroll buttons and easy navigation control access to secondary functions. Create custom displays too 0.025% Basic DC accuracy 100 kHz ac bandwidth True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads Measure up to 10A ( 20 A for 30 seconds; 10A continuous) 100 mF capacitance range Temperature function Relative mode to remove test lead resistance from low ohms or capacitance measurements Peak capture to record transients as fast as 250 ¼ s Premium test leads and alligator clips included Optical USB PC communication interface allows for easy PC download to document logged data with FVF software ( not included) Limited lifetime warranty CAT III 1000 V / CAT IV 600 V safety rated Specifications Voltage DC Accuracy 0.025 % Range and Resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V Voltage AC Accuracy 0.4 % ( true-rms) Range and Resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V Current DC Accuracy 0.06 % Range and Resolution 500.00 µ A, 5000.0 µ A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A Current AC Accuracy 0.61 % ( true-rms) Range and Resolution 500.00 µ A, 5000.0 µ A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A Temperature ( excluding probe) Accuracy 1.0 % Range and Resolution -200.0 ° C to 1350.0 ° C ( -328.0 ° F to 2462.0 ° F) Resistance Accuracy 0.05 % Range and Resolution 500.00 & , 5.0000 k& , 50.000 k& , 500.00 k& , 5.0000 M& , 50.00 M& , 500.0 M& Resistance 10 50 & ( 2 wire connection) Accuracy 0.15 % + 20 Range and resolution 50.000 & Capacitance Accuracy 1.0 % Range and Resolution 1.000 nF, 10.00 nF 100.0 nF, 1.000 µ F, 10.00 µ F, 100.0 µ F, 1000 µ F, 10.00 mF, 100.00 mF & Frequency Accuracy 0.005% + 1 Range and Resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz Additional functions/ features Multiple on-screen displays Yes True-rms AC bandwidth 100 kHz DBV/ dBm Yes DC mV resolution 1 ¼ V Megohm range Up to 500 M Conductance 50.00nS Continuity beeper Yes Battery/ Fuse access Battery / Fuse Peak 250 ¼ S Elapse time clock Yes Time of day clock Yes Min-Max-Avg Yes Frequency Yes Duty Cycle 0.01 % to 99.99 % Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms Hold Yes Isolated Optical Interface Yes Auto/ Touch Hold Yes Reading memory Yes Log to PC Yes Interval/ Event Logging Yes Logging Memory Up to 10, 000 readings Resistance Low Ohm 0.001 © to 50.000 © 10 mA source LoZ Yes Low Pass Filter Yes Environmental Specifications Operating Temperature -20 ° C to + 55 ° C Storage Temperature -40 ° C to + 60 ° C Relative Humidity 0% to 90% ( 0 ° C - 37 ° C) 0% to 65% ( 37 ° C - 45 ° C) , 0 to 45 % ( 45 ° C - 55 ° C Electromagnetic Compatability EMC EN6 1326-1 Vibration Random vibration per MIL-PRF-28800f Class 2 Shock 1 meter drop per IEC/ EN 61010-1 2nd edition Safety Specifications Overvoltage category CAT III 1000 V / CAT IV 600 V safety rated Agency Approvals CSA, UL, TÜ V, CE Mechanical & General Specifications Maximum voltage between any terminal and earth ground 1000V Size ( HxWxL 22.2 cm x 10.2 cm x 6 cm ( 8.75 in x 4.03 in x 2.38 in) Weight 870.9 g ( 28 oz) Battery Life 100 minimum, 200 hours in logging mode Battery type 6 AA alkaline batteries, NEDA 15A IEC LR6

Tampilkan Lebih Banyak